lqh32pn100mncl Cross Section Analysis Report
Date:2024-02-29 16:50:08 Views:297 Author:CHUANGXIN ONLINE TESTING LAB
Sample Type: LQH32PN100MNCL The internal structure of the 2 PCS samples(1 PCS D/C 2340, 1 PCS of D/C 2344)was consistent in the slice test. 1. Golden sample(D/C 2340) End electrode copper wire diameter : 0.10 mm Internal winding coil diameter : 0.12 mm Internal medium thickness : 0.75 mm Plastic sealing thickness : 0.37 mm 2. Test sample(D/C 2344) End electrode copper wire diameter : 0.10 mm Internal winding coil diameter : 0.13 mm Internal medium thickness : 0.75 mm Plastic sealing thickness : 0.35 mm Summarize : Slice comparison reveals consistent structure between two pieces.