Damp heat test refers to the test to evaluate the antirust performance of antirust grease on metal under the condition of high temperature and high humidity. GB / T 2423.3-2006 / iec60068-2-78:2001 environmental testing of electrical and electronic products Part 2: Test methods Test cab: constant damp heat test this test standard is mainly applicable to determine the adaptability of electrical and electronic products, components or equipment during use, storage and transportation under high humidity conditions.

This part specifies the severity of the test, such as high temperature, high humidity and duration This part is applicable to heat dissipation and non heat dissipation samples

This part is applicable to small equipment and components, as well as large equipment with complex connection of test devices outside the test box. This connection requires a certain assembly time. During installation, preheating or specific test conditions can not be maintained.

湿热试验是什么?湿热试验的检测标准及报告

The severity levels of constant damp heat test include: test temperature value, test humidity and test time.

Damp heat test conditions:

30 ℃, humidity 93%

30 ℃, humidity 85%

40 ℃, humidity 93%

40 ℃, humidity 85%

The test time is generally 12h, 16h, 24h, 2D, 4D, 10d, 21d and 56d

Application scope of damp heat test:

It is applicable to the adaptability test of electrical, electronic, instrument and other products, parts and materials during storage, transportation and use in high and low temperature alternating humid and hot environment; It is applicable to the cold, heat, moisture and dry resistance test of various electronic, electrical, electrical, plastic and other raw materials and devices and the reliability test equipment of quality control engineering; It is suitable for high temperature, low temperature and humidity resistance cycle test of optical fiber, LCD, crystal, inductor, PCB, battery, computer, mobile phone and other products.

The detection standards of damp heat test are as follows:

Environmental tests for electric and electronic products Part 2: Test methods Test cab: constant damp heat test GB / T 2423.3-2006 / iec60068-2-78:2001

Environmental testing for electric and electronic products Part 2: Test methods Test DB: alternating damp heat (12h + 12h cycle) GB / t2423 4-2008/IEC 60068-2-30:2005

Packaging - Basic tests for transport packages - Part 2: temperature and humidity conditioning treatment (GB / T 4857.2-2005 / ISO 2233:2000)

Basic technical conditions for automotive electrical equipment QC / T 413-2002

Military equipment laboratory environmental test methods Part 9: Damp heat test GJB 150.9a-2009

General specification for military computer GJB 322a-1998

General specification for military communication equipment GJB 367a - 2001

General specification for military electronic test equipment gjb3947a-2009

Environmental test of ship electronic equipment constant damp heat test GJB 4.5-1983

Environmental test of ship electronic equipment alternating damp heat test GJB 4.6-1983

Rail transit rolling stock electronic devices GB / T 25119-2010 / IEC 60571:2006

General specification for electronic measuring instruments GB / T 6587-2012

High temperature and low temperature test methods for railway ground signal products TB / T 2953-1999

Test methods and procedures for microelectronic devices GJB 548b-2005

Test methods for electronic and electrical components GJB 360b-2009

Environmental test Part 2: Test methods Test Cy: constant damp heat is mainly used for accelerated test of components GB / T 2423.50-2012 / IEC 60068-2-67:1995

Laboratory test report of high and low temperature damp and hot environment test:

Damp heat test standard: GB / t1740-1979 adopts the constant temperature and humidity test cycle method, with the temperature of (47 ± L) ℃ and the relative humidity of (96 ± 2)%. The same method is adopted by ASTM d2247, with the temperature of (38 ± L) ℃ [(100 ± 2) ° F] and the relative humidity of 100%. There is always condensate on the sample plate. Some foreign standards also adopt high temperature short cycle and temperature humidity alternating test cycle.

The constant temperature and humidity test method is to prepare test pieces according to corresponding standards, such as GB / t1765 - 1979 or ASTM D609, and record the original state of the sample plate. Hang the template vertically on the template frame, and the front of the template shall not contact. Put it into a temperature and humidity regulating box with a temperature of (47 ± 1) ℃ and a relative humidity of (96 ± 2)%. When it rises to the specified temperature and humidity, the test time shall be calculated. There shall be no condensation on the sample surface during the test. Check once every 48h after continuous test. After two inspections, check every 72h. After each inspection, the position of the template shall be changed. The last inspection shall be conducted according to the time specified in the product standard. If there is no product standard, the inspection time can be determined according to the specific situation.